Pembroke Instruments | Extended infrared imaging

Extended SWIR (eSWIR) Camera Applications

Reveal material and molecular contrast beyond conventional 1.7 µm SWIR imaging. Pembroke Instruments offers deeply cooled cameras for scientific research, industrial inspection, laser measurements and wavelength-selective imaging extending to 2,550 nm.

Extended SWIR · T2SLZephIR 2.5e extended SWIR camera

ZephIR 2.5e

1,000–2,500 nm | 640 × 512
55% peak QE, selectable gain, 45 e⁻ typical high-gain read noise and exposure down to 1 µs. A strong candidate for short-exposure measurements, laser profiling and optical research.

NEW · Extended SWIR · MCTFLOE 2.5s extended SWIR camera, rear and side view

FLOE 2.5s

800–2,550 nm | 640 × 512
88% peak QE, 1 Me⁻/pixel/s typical dark current, up to 235 fps full frame and 6,900 fps ROI. A strong candidate for longer exposures, weak spectral signals and compact OEM integration.

Which eSWIR Camera Is Best for Your Application?

Use this application selection matrix to identify a starting point for your imaging system. Both cameras cover the principal extended SWIR absorption bands.

ApplicationTypical wavelengthsZephIR 2.5eFLOE 2.5sSelection rationale
Material identification and plastics sorting1,700–2,500 nmStrong fit: bright, controlled illuminationPreferred candidate: weak filtered signals or longer exposuresHigher QE and lower dark current favor FLOE when photon collection or integration time is limiting.
Chemical and pharmaceutical imaging2,000–2,500 nmStrong fit: short exposures in high gainPreferred candidate: longer-exposure spectral mappingFLOE has 30× lower listed dark current; ZephIR high gain has lower read noise. Compare actual signal-to-noise.
Food, agriculture and moisture inspection1,450–2,350 nmStrong fit: well-lit, fast inspectionPreferred candidate: weak reflection near 1,940 nmStrong water absorption reduces reflected light; FLOE may benefit longer exposures.
Semiconductor inspection and microscopy1,200–2,500 nmStrong fit: short-exposure, high-gain imagingPreferred candidate: low-throughput, longer-exposure microscopySilicon transmission depends on doping, thickness and wavelength; compare read noise and dark current.
Mineral and geological imaging2,100–2,500 nmStrong fit: illuminated samplesPreferred candidate: weak bands and longer exposuresFLOE offers coverage to 2,550 nm and lower dark current.
2 µm laser beam profiling1,900–2,100 nmPreferred candidate: bright beams and short exposuresStrong fit: weak beams or high-speed ROIZephIR offers 1 µs minimum exposure and 1.4 Me⁻ low-gain full well; FLOE offers up to 6,900 fps ROI. Use calibrated attenuation.
Field imaging and OEM integrationApplication dependentStrong fit: controlled environmentsPreferred candidate: compact systems and wider ambient rangeFLOE weighs 1.9 kg, operates from −20 to 50 °C and has an available OEM version.
Product detailsView ZephIR 2.5eView FLOE 2.5sAsk an applications engineer

Engineering selection guidance, not comparative test results. Higher peak quantum efficiency does not guarantee higher sensitivity at every wavelength. Confirm spectral QE, dark current, read noise, exposure, frame rate and saturation limits before selecting a camera.

Six Key Applications of Extended SWIR Imaging

Longer infrared wavelengths provide access to absorption features that help distinguish materials with similar visible appearance.

Plastic recycling conveyor with mixed polymers

Illustrative application image

01 · 1,700–2,500 nm

Material Identification and Plastics Sorting

Use wavelength-dependent reflectance to differentiate polymers and evaluate material uniformity. Additional C–H absorption features beyond 1.7 µm can improve discrimination between visually similar materials.

  • PE, PP, PET and PVC classification
  • Textiles, composites and recycled materials
  • Contamination and coating inspection
Discuss material identification →
Pharmaceutical tablets for chemical imaging

Illustrative application image

02 · 2,000–2,500 nm

Chemical and Pharmaceutical Imaging

Resolve spatial differences in chemical composition with selected absorption bands. Multispectral or hyperspectral configurations can support ingredient and process characterization.

  • Tablet and powder blend uniformity
  • Coatings, adhesives and chemical distribution
  • Process analytical technology feasibility studies
Discuss chemical imaging →
Apples on a food inspection conveyor

Illustrative application image

03 · 1,450 and 1,940 nm

Food, Agriculture and Moisture Inspection

The strong water absorption region near 1.94 µm provides additional contrast for moisture-sensitive inspection. Other bands can support calibrated studies of fats, proteins and carbohydrates.

  • Drying and moisture uniformity
  • Food quality and foreign-material screening
  • Agricultural sample characterization
Discuss moisture imaging →
Silicon wafer under an inspection instrument

Illustrative application image

04 · 1,200–2,500 nm

Semiconductor Inspection and Microscopy

Image through suitable silicon substrates and evaluate wavelength-dependent contrast in layered devices. Longer wavelengths provide additional options, although transmission depends on doping, thickness and coatings.

  • Bonded wafer and advanced packaging inspection
  • Subsurface structures and alignment marks
  • Infrared microscopy of materials and devices
Discuss semiconductor imaging →
Rock sample with illustrative false-color mineral mapping

Illustrative application image

05 · 2,100–2,500 nm

Mineral Identification and Geological Imaging

Selected bands around 2.2–2.35 µm are valuable for distinguishing hydroxyl-bearing minerals and carbonates with wavelength-resolved measurements.

  • Geological core and rock sample mapping
  • Clay and carbonate identification
  • Ore sorting feasibility and mineral exploration
Discuss mineral imaging →
Illustrative two-dimensional and three-dimensional laser intensity profiles

Illustrative application image

Featured optical application · 1,900–2,100 nm

2 µm Laser Beam Profiling

Capture two-dimensional laser intensity distributions beyond the cutoff of typical InGaAs cameras. Evaluate beam shape, alignment and uniformity with appropriate attenuation and calibration.

  • Thulium and holmium laser systems
  • Supercontinuum source characterization
  • Optical alignment and beam stability
Discuss laser profiling →

Why Imaging Beyond 1,700 nm Matters

Standard SWIRZephIR 2.5eFLOE 2.5s80010001500170020002500Wavelength (nm)

Nominal wavelength coverage only; bars do not represent quantum efficiency or sensitivity curves.

Approximate wavelengthAbsorption featureImaging opportunity
1,450 nmO–H / waterMoisture contrast
1,700–1,800 nmC–H overtonesPolymers, hydrocarbons
1,940 nmWater combination bandMoisture distribution
2,050–2,180 nmN–H and other combination bandsProtein and chemical studies
2,200–2,250 nmAl–OH featuresClay minerals
2,250–2,400 nmC–H combination bandsPolymers, oils and fats
2,300–2,350 nmCarbonate featuresMineral discrimination

Bands are indicative and can overlap. Actual wavelength selection depends on the sample, illumination and measurement geometry.

Compare Pembroke Extended SWIR Cameras

SpecificationZephIR 2.5eFLOE 2.5s
DetectorT2SLHgCdTe (MCT)
Spectral range1,000–2,500 nm800–2,550 nm
Resolution640 × 512640 × 512
Pixel pitch15 µm15 µm
Peak QE55%88%
CoolingTEC + forced air, −80 °CFive-stage TEC + forced air, −80 °C
Frame rate240 fps170 fps low-noise / 235 fps high-speed
InterfaceUSB 3.0 / Camera LinkUSB 3.0 / Camera Link
Typical dark current30 Me⁻/pixel/s1 Me⁻/pixel/s
Typical readout noise45 / 75 / 300 e⁻ (high / medium / low gain)215 / 280 e⁻ (low-noise / high-speed mode)
Typical full well28 / 110 / 1,400 ke⁻ (high / medium / low gain)1,000 ke⁻ in both modes
Minimum integration time1 µs50 µs
Maximum ROI rate4,000 fps6,900 fps (high-speed); 5,200 fps (low-noise)
Typical operability>99%>99.5%
Digitization14 bits14 bits
Image formats16-bit HDF5, FITS, TIFF16-bit HDF5, FITS, TIFF
External controlTrigger IN/OUTTrigger IN/OUT
SDKC++ / PythonC/C++ / Python
Ambient temperature10 to 35 °C−20 to 50 °C
Power12 VDC24 VDC
Dimensions169 × 130 × 97.25 mm84 × 84 × 160 mm
Weight2.9 kg1.9 kg
OEM versionNot specified in product pageAvailable
Product detailsView ZephIRView FLOE

Specifications from the Pembroke product pages. Read noise and full well are mode-dependent; the lowest noise and largest full well do not occur in the same ZephIR gain mode. ROI rates depend on configuration. Peak QE alone does not establish relative sensitivity at a particular wavelength; compare spectral QE, dark current, read noise and exposure conditions for your application.

Quantum Efficiency and Camera Selection

FLOE: higher QE and lower dark current

At −80 °C the supplied spectral comparison shows higher FLOE quantum efficiency across much of the measured range. Its listed dark current is 30 times lower, which can be particularly useful for longer integrations.

ZephIR: selectable gain and short exposures

High gain provides 45 e⁻ typical read noise with 28 ke⁻ full well. Low gain provides 1.4 Me⁻ full well with 300 e⁻ read noise. Exposure down to 1 µs supports bright-source measurements.

For a first-order signal-to-noise estimate, use signal electrons divided by the square root of signal electrons + dark-current electrons + read-noise variance. Include optical background, saturation and wavelength-specific QE in the final evaluation. Neither camera is universally more sensitive.

FLOE 2.5s and ZephIR 2.5e quantum efficiency comparison at minus 80 degrees Celsius
Spectral response comparison at −80 °C, reproduced from the supplied FLOE product page.

Designing an eSWIR Imaging System

Optics and illumination

Specify lens and window transmission over the required wavelength range. Select illumination with sufficient spectral output, or suitable attenuation for laser imaging. Consider working distance, field of view and spatial resolution.

Spectral selection and calibration

Use narrowband filters, tunable illumination or spectral imaging optics for composition measurements. Dark and reference images, flat-field correction and sample-specific calibration help separate material effects from illumination and detector response.

Broadband versus hyperspectral: An eSWIR camera measures integrated intensity across its sensitive band unless wavelength selection is added. Quantitative chemical identification generally requires multiple spectral measurements and validated reference data.

Additional research and industrial applications

Other candidates include K-band astronomy, high-temperature process monitoring, tissue hydration research and wavelength-selective gas imaging. Gas detection requires appropriate spectral filtering, adequate optical path length and sensitivity; calibrated temperature measurement requires a suitable radiometric system.

Frequently Asked Questions

What is the difference between SWIR and extended SWIR?

Conventional InGaAs cameras commonly operate from 900 to 1,700 nm. Extended SWIR detectors reach longer wavelengths, such as 2,500 or 2,550 nm, enabling access to additional absorption features.

Can an eSWIR camera identify chemicals directly?

Not from broadband intensity alone in most cases. Wavelength-selective imaging and calibrated classification methods are commonly necessary.

Which camera is best for my application?

Selection depends on the required wavelength, optical throughput, detector noise, exposure, speed and integration requirements. Pembroke can help evaluate both models.

Can I use my existing SWIR lens?

Possibly. Verify lens transmission, coatings, focus and image quality through the longest wavelength needed. A standard 1.7 µm SWIR lens may not be suitable for 2.55 µm imaging.