200–800 nm UV-Vis
Broad UV-Visible measurement range on the ASURYAN platform; verify range by configuration.
Real-time, multichannel UV-Visible spectroscopy for liquid process development, pharmaceutical and biotechnology manufacturing, and industrial process analytical technology (PAT).
Measure, analyze and predict — from laboratory development to in-line production monitoring, with flexible sampling interfaces and solutions for hazardous process areas.
Talk to an Engineer / Request a QuoteExplore configurations
Broad UV-Visible measurement range on the ASURYAN platform; verify range by configuration.
Select single-channel or three-channel configurations to monitor multiple sampling points or optical path lengths.
Internal source-reference monitoring and compensation options support long-term reproducibility.
Connect compatible flow cells, immersion probes, transmission and multi-angle interfaces.
Use spectroscopy for PAT, calibration models, and automated process feedback.
Nova provides industrial-PC, OPC-UA and compliance-oriented software capabilities; validate deployment requirements with the manufacturer.
Choose a flexible UV-Vis analyzer for liquid-process development, an integrated platform for automated and regulated workflows, or a protected installation for hazardous areas. The right configuration depends on measurement points, sample interfaces, data integration and site classification.



Application imagery illustrates relevant process environments; it does not establish a specific installed instrument or certification.
Capabilities. The ASURYAN industrial analyzer measures UV-Visible absorbance across the 200–800 nm region. Its rugged stainless-steel housing and fiber-optic sampling architecture make it suitable for deployment close to liquid processes rather than relying exclusively on offline laboratory sampling. The source material describes single- or multiple-channel configurations, including three simultaneous measurement channels with dedicated spectrometers and an internal channel for monitoring illumination stability.
Fiber-coupled transmission, transflexion and ATR sampling options, as well as flow cells and multi-angle optical arrangements, allow the measurement geometry to be matched to the sample. Simultaneous channels can support multiple sampling locations or optical paths, reducing the need for sequential measurements. Continuous source monitoring helps identify or compensate for light-output drift.
Discuss ASURYAN UV-Vis


Application imagery illustrates relevant process environments; it does not establish a specific installed instrument or certification.
Capabilities. Nova combines high-performance UV-Vis analysis with an embedded industrial PC, deterministic acquisition controls and software designed for integration into automated processes. One- and three-channel versions are available. In the three-channel version, independent simultaneous measurements avoid multiplexing delays; each channel can use its own integration settings to accommodate differing sample conditions. A dedicated internal reference spectrometer continuously monitors light-source output.
Nova supports OPC-UA communications and connectivity with LIMS-oriented workflows. Its dual-layer architecture separates the analytical acquisition engine from the supervision and workflow environment. The manufacturer's documentation describes audit trails, controlled configurations and automated Operational Qualification (OQ) and Routine System Verification (RSV) procedures that produce reports, helping teams plan validation and ongoing system checks. Compatible optical interfaces include immersion probes, flow cells, multi-angle cuvette holders and ATR probes.
Regulatory suitability, including 21 CFR Part 11-related requirements, depends on the selected software configuration, qualification and the customer's validated use.
Discuss ASURYAN Nova

Application imagery illustrates relevant process environments; it does not establish a specific installed instrument or certification.
Capabilities. The ASURYAN ATEX solution places a compatible ASURYAN or ASURYAN Nova analyzer in a certified, overpressure-protected enclosure for designated hazardous gas atmospheres. The supplied documentation identifies a Zone 1, Category 2 enclosure designed around ATEX Directive 2014/34/EU and IEC 60079 requirements. The protection system is designed to prevent an explosive atmosphere from reaching the instrument electronics while retaining UV-Vis analytical functionality.
The protected enclosure combines overpressure management, monitored safety functions and temperature control with a cleanable industrial exterior. It can accommodate compatible optical interfaces, including flow cells and probes, and supports configurations with up to three measurement channels. This allows operators to bring continuous UV-Vis measurements closer to hazardous process streams while limiting the need to move samples to a remote laboratory.
Hazardous-area suitability must be verified against the exact enclosure certificate, gas group, temperature class, site classification, installation requirements and local regulations. A Class I Division 1 option is described as available on request; it is not interchangeable with ATEX certification.
Discuss ASURYAN ATEXSpecifications and features summarized from the supplied ASURYAN, Nova and ATEX documentation. Confirm the final hardware, optical interface and software package before ordering.
Use this application guide to identify a recommended starting configuration and open its brochure. ASURYAN Nova is particularly suited to integrated automation and regulated workflows; ATEX is intended for appropriately classified hazardous areas. Final selection depends on measurement range, sample interface, site requirements and process integration.
| Application | Recommended ASURYAN model | Why this configuration | Product brochure / supporting PDF |
|---|---|---|---|
| Protein concentration in bioprocessing | ASURYAN UV-Vis | Inline protein quantification with suitable transmission, transflection or flow-cell optical paths. | UV-Vis brochure (PDF) Application PDF |
| Protein aggregation and turbidity | ASURYAN UV-Vis | Monitor changes in UV absorbance and scattering during biologics development. | UV-Vis brochure (PDF) Application PDF |
| Cleaning-in-place (CIP) verification | ASURYAN UV-Vis; ASURYAN ATEX for classified areas | Measure UV-active cleaning residues in rinse water; confirm detection limits for each analyte. | UV-Vis brochure (PDF) ATEX brochure (PDF) Application PDF |
| Vaccine and biologics production | ASURYAN UV-Vis | Monitor protein adsorption and formulation-related process parameters. | UV-Vis brochure (PDF) Application PDF |
| LNP-encapsulated API analysis | ASURYAN UV-Vis | UV analysis of selected APIs in lipid nanoparticle samples with validated chemometric models. | UV-Vis brochure (PDF) Application PDF |
| Syringe leak / container closure studies | ASURYAN UV-Vis | Quantify methylene-blue dye in syringes using a dedicated sample holder. | UV-Vis brochure (PDF) Application PDF |
| Vial and liquid inspection | ASURYAN UV-Vis | Use transmission and multi-angle optical sampling with vial or cuvette holders. | UV-Vis brochure (PDF) Application PDF |
| Liquid color and formulation monitoring | ASURYAN UV-Vis | Measure solution color and apply appropriate calibration methods. | UV-Vis brochure (PDF) Application PDF |
| Automated GMP / PAT process monitoring | ASURYAN Nova | Integrated industrial PC, OPC-UA connectivity and validation-oriented workflows. | Request Nova brochure The Nova brochure has not yet been assigned a verified published URL. |
| Hazardous-area chemical and solvent processing | ASURYAN ATEX | Protected analyzer enclosure for appropriately classified ATEX Zone 1 applications. | ATEX brochure (PDF) Application PDF |
Recommendations are application-based starting points, not exclusive model assignments. Consult Pembroke Instruments for a quotation and to confirm instrument configuration and suitability.
Measure protein concentration in-line, including high and low concentration ranges using suitable optical paths.
Track changes in absorption and scattering associated with aggregation and process quality.
Monitor rinse water and detect UV-active residues, with analyte-specific calibration and detection limits.
Support real-time monitoring and quality-oriented production workflows.
Measure UV-active APIs, including selected lipid nanoparticle and supercritical-fluid process use cases.
Inspect dye traces, solution color, and liquid characteristics using transmission or multi-angle sampling.
Flow cell, probe, cuvette or vial interface
UV-Vis spectra with reference monitoring
Absorbance, concentration and chemometric methods as appropriate
Support process monitoring and automation decisions
Examples drawn from the supplied manufacturer documents. Results are application-specific; analytical sensitivity and model performance must be established for each sample matrix and configuration.
Monitor protein concentration, IgG aggregation and cleaning residues with multiple optical paths.
Source: In-line inspection of protein production Asuryan.pdf
Detect changes associated with aggregation during processing.
Source: In-line detection of protein aggregation Asuryan.pdf
Process monitoring in vaccine production workflows.
Source: Vaccine Production using SAM FLEX and Asuryan.pdf
UV spectroscopy for monitoring encapsulated active ingredients.
Source: In-line quantification of API encapsulated in LNPs using UV spectroscopy.pdf
Methylene-blue transmission measurements and multivariate calibration.
Source: Detection of leaks in syringes Asuryan.pdf
Spectral measurement of liquid color and consistency.
Source: Determination of solutions color using Asuryan.pdf
Qualitative and quantitative analysis of protein solutions.
Source: Detection and quantification of proteins in solution Asuryan.pdf
Analyze vitamin concentrations in liquid blends.
Source: Detection and quantification of vitamins in solution Asuryan.pdf
PDF links open manufacturer-authored documents with Pembroke Instruments U.S. contact information. Performance and suitability depend on the selected system and application.
| Capability | ASURYAN UV-Vis | ASURYAN Nova | ASURYAN ATEX solution |
|---|---|---|---|
| Spectral range | 200–800 nm (documented standard) | UV-Vis; confirm exact model specification | Per installed ASURYAN system |
| Measurement channels | 1 or 3, depending on version | 1 or 3, plus internal source reference | Compatible with 3-channel configurations |
| Spectral resolution | < 6.5 nm FWHM (liquid-process brochure) | Confirm current datasheet | Per installed analyzer |
| Sampling | Flow cells and immersion probes | Flow cells, probes and multi-angle options | Process-compatible sampling interfaces |
| Automation | Computer / process control options | Embedded industrial PC, PLC runtime, OPC-UA | Depends on integrated analyzer |
| Environment | Industrial / lab processes | Lab and industrial processes | ATEX Zone 1 enclosure solution |
Specifications consolidated from the supplied brochures; not every feature is available on every model. Confirm ordering codes, certification and latest datasheet before publication or quotation.
Tell Pembroke Instruments about your target analytes, concentration range, sampling geometry, process temperature and pressure, hazardous-area classification, and automation requirements. We can help determine an appropriate spectrometer and sampling configuration.
Request Specifications or a Quote