Application evidence, case studies & technical literature
The following manufacturer technical documents support the measurement capabilities described above. Performance depends on the sample matrix, calibration, probe configuration and process integration. Request the underlying application study and validation data for your specific process.
Tablet and capsule analysis — multipoint NIR spectroscopy
Technical basis: The SAM-SPEC NIR brochure describes spatially resolved NIR measurement for tablets and capsules, including API content, dosage uniformity, contamination detection and batch sorting. It specifies 900–1650 nm operation, 2 ms acquisition and up to 27 measurement channels, depending on configuration.
Relevant applications: Tablet press monitoring, coating and homogeneity assessment, at-line and in-line product quality inspection.
Source: SAM-SPEC NIR spectroscopy manufacturer brochure (January 2024), pages 2–4. These are stated manufacturer capabilities, not independent performance validation.
Read the technical documents: Request tablet and capsule application data
Lyophilized product inspection — SAM-SPEC Lyo
Technical basis: The SAM-SPEC Lyo technical document describes non-destructive assessment of residual moisture, lyocake homogeneity, glass particles and meltback. It specifies a residual-moisture detection threshold of 0.2%, a stated water-content range of 0.2–5% and analysis time under 5 ms.
Relevant applications: Freeze-drying process development, vial inspection, packaging-line quality control and Quality-by-Design workflows.
Source: SAM-SPEC Lyo patented technique manufacturer document (April 2023), pages 1–2. The stated threshold and range require application-specific validation.
Read the technical documents: Request lyophilization case studies
Powder blend and feedframe monitoring
Technical basis: Manufacturer literature identifies real-time feedframe powder analysis, API concentration and blending uniformity as SAM-SPEC NIR applications, including measurements across different positions relative to the light source.
Relevant applications: Powder blend uniformity, pharmaceutical continuous manufacturing and process monitoring.
Source: SAM-SPEC NIR spectroscopy manufacturer brochure (January 2024), page 3, and SAM-SPEC Multipoint NIR spectroscopy system presentation, page 9.
Read the technical documents: Request powder and feedframe application data
Multi-angle UV-Vis/NIR analysis of vials and cuvettes
Technical basis: The UV-Vis/NIR Vial Analyzer document specifies five SMA connectors and optical measurements at multiple angles, including collimated transmission, scattered transmission and backscattering. It supports 2, 3, 5 and 10 mm cuvette path lengths with spacers.
Relevant applications: Liquid sample characterization, vial and syringe measurements, and laboratory method development.
Source: UV-Vis/NIR Vial Analyzer manufacturer document (June 2024), page 1. This accessory is a distinct measurement solution; do not interpret its specifications as SAM-SPEC NIR acquisition-unit specifications.
Read the technical documents: Request vial analyzer technical information
The linked documents are hosted in the Pembroke Instruments WordPress Media Library. Technical results are application-specific and may require independent validation.