Semiconductor, PCB & Electronics Failure Analysis

SWIR & Thermal Microscopy for Semiconductor and Electronics Inspection

Use two complementary imaging methods to answer two different failure-analysis questions: What is hidden beneath the surface? and Where is electrical energy becoming heat? Pembroke Instruments supplies SWIR microscope solutions for through-silicon and subsurface inspection, plus thermal microscope systems for localized temperature mapping of powered electronics.

  • SWIR microscopy: inspect silicon wafers, dies, bonded interfaces, MEMS, TSVs and semiconductor packages.
  • Thermal microscopy: locate PCB hot spots, leakage paths, short circuits, abnormal power dissipation and thermal gradients.
  • Combined workflow: correlate internal structure with operating temperature behavior to accelerate root-cause analysis.
  • Application support: define field of view, magnification, working distance, optics, illumination, camera and integration requirements.
Pembroke SWIR microscope for semiconductor and electronics inspection

Configurable SWIR microscope platform for wafer, die, MEMS, bonded-interface and package inspection.

Through-Silicon ImagingReveal selected structures and defects hidden from visible cameras
Temperature MappingVisualize hot spots and localized heating while devices operate
Microscope-Scale InspectionConfigure magnification, field of view and working distance
Application IntegrationOptics, illumination, positioning, software and camera selection

Two Imaging Modes, Different Information

Choose the Microscopy Technique Based on What You Need to See

Visible microscopy is often the starting point, but it cannot provide every answer. SWIR and thermal microscopy extend inspection in different directions: SWIR can reveal selected subsurface structures through silicon, while thermal imaging converts temperature distribution into a spatial map of circuit or device behavior.

SWIR Microscopy

See Internal Structure Through Silicon

Silicon strongly absorbs visible light but becomes substantially more transmissive at suitable near-infrared and SWIR wavelengths. With appropriate optics and illumination, InGaAs SWIR cameras can support non-destructive inspection of structures and defects that may be hidden beneath the surface.

  • Silicon wafer inspection
  • Die and IC inspection
  • Wafer bonding and bonded interfaces
  • Flip-chip and advanced packaging
  • MEMS and TSV analysis
  • Cracks, voids, contamination and alignment errors
Thermal Microscopy

See Where Electrical Energy Becomes Heat

A thermal microscope shows temperature distribution rather than visible structure. On powered boards and devices, it can quickly identify abnormal heating and guide electrical probing or deeper failure analysis toward the most likely problem area.

  • PCB hot-spot localization
  • Overheating ICs and power devices
  • Short circuits and leakage paths
  • Abnormal power dissipation
  • Thermal gradients and poor heat spreading
  • Transient and intermittent thermal signatures

Thermal Microscope Spotlight

High-Magnification Thermal Imaging for PCB, IC and Semiconductor Analysis

Thermal microscopy adds quantitative temperature information to small-area inspection. Instead of showing only physical structure, it maps where heat is generated, how it spreads, and how a device changes as power, load or operating conditions change.

Pembroke Instruments can configure a complete thermal microscope system around the sample and test requirement. A typical platform combines a 640 × 512 LWIR thermal camera, macro or microscope optics, vertical mounting, a sample translation stage, an optical breadboard and radiometric analysis software.

  • Non-contact inspection: measure temperature without touching delicate boards, wafers, coatings or devices.
  • Radiometric data: collect temperature information at every image pixel, not just a qualitative thermal picture.
  • Fine thermal detail: approximately 20 µm spatial resolution for IC/PCB imaging, depending on optics, working distance and setup.
  • Wide measurement capability: typical configured range from -20°C to +550°C.
  • Dynamic testing: compare startup, idle and load conditions and follow changing hot spots over time.
  • Electrical correlation: software can synchronize thermal curves with voltage and current measurements.
640 × 512LWIR sensor format
~20 µmTypical IC/PCB spatial resolution, setup dependent
-20°C to +550°CTypical configured measurement range
RadiometricTemperature data for every image pixel

Expanded Thermal Microscopy Applications

Where Microscopic Temperature Differences Reveal the Problem

Thermal microscopy is useful whenever a small heat source, gradient or transient temperature change provides a clue to performance, manufacturing quality or failure mechanism.

Thermal

PCB & Electronics Testing

Locate overheating components, short circuits, leakage paths, high-resistance connections and unexpected power dissipation across operating circuit boards.

Thermal

Semiconductor Failure Analysis

Identify localized heating, leakage current, package-related thermal behavior and temperature non-uniformity in ICs and semiconductor devices.

Thermal

Power Electronics

Analyze heating in power devices, regulators, MOSFETs, connectors and thermal-management structures under controlled load conditions.

Thermal

Solar Cell Inspection

Look for hot spots, shunts, non-uniform heating and other thermal signatures associated with defective photovoltaic cells and materials.

Thermal

Materials Research

Measure thermal behavior in coatings, films, composites, microstructures and phase-change materials where conventional thermal cameras lack enough spatial detail.

Thermal

Photonics & Laser Testing

Evaluate absorption-induced heating, optoelectronic components, laser-exposed materials and package-level thermal effects.

Complete Thermal Microscope Configuration

Camera, Optics, Stage and Software Work as One Measurement System

A microscope application cannot be specified from sensor resolution alone. Sample size, target feature size, working distance, optics, stage geometry, temperature range and analysis workflow all determine whether the system will resolve the thermal behavior that matters.

  • LWIR camera: 640 × 512 sensor format for detailed thermal imaging.
  • Optics: standard configurations can include a 50 mm macro lens, with objective options for different fields of view and working distances.
  • Mechanical platform: vertical mounting, optical breadboard and sample translation stage support repeatable positioning.
  • Radiometric software: record full thermal video, analyze temperature curves and compare behavior over time.
  • Synchronized measurements: correlate thermal data with voltage and current during device operation.

What Pembroke Needs to Recommend a Thermal Microscope

For the fastest application review, provide the sample dimensions, smallest hot spot or feature of interest, required field of view, available working distance, expected temperature range and whether the device will be powered during inspection.

If electrical data must be synchronized with the thermal measurement, include the voltage/current test workflow as well.

Thermal imaging microscope resolution example for fine PCB and IC thermal features

PCB and IC-level thermal detail: use calibrated targets and real device imagery to verify that the optics and field of view provide enough spatial resolution for the feature being investigated.

Technique Selection

SWIR, Thermal—or Both?

Inspection QuestionBest Starting TechniqueWhat It Can Add
Is there a crack, void, interface defect or structure beneath silicon?SWIR microscopyNon-destructive subsurface contrast through silicon at suitable wavelengths.
Which component or region is overheating on a powered PCB?Thermal microscopyFull-field visualization of localized temperature rise and thermal gradients.
Is a bonded interface aligned or complete?SWIR microscopyInspection of selected bonded layers, air gaps, voids and alignment problems.
Is a suspect IC dissipating more power than expected?Thermal microscopyComparison of heating behavior under startup, idle or controlled load.
Do I need to correlate an internal feature with abnormal heating?Use bothSWIR provides structural information; thermal microscopy provides operating temperature behavior.
Where should I probe electrically or inspect more closely?Thermal first, then targeted inspectionThermal imaging can identify where to look first; SWIR or visible microscopy can then examine structure at that location.

Primary Applications

Microscopy Applications Across Semiconductors, PCBs and Electronics

SWIR

Silicon Wafer & Die Inspection

Inspect wafers and dies for cracks, edge damage, selected internal non-uniformities and structures that may be obscured in visible imaging.

SWIR

Bonding, MEMS & TSV Analysis

Investigate bonded interfaces, voids, air gaps, channels, cavities, alignment and through-silicon structures using microscope optics and controlled SWIR illumination.

SWIR

Advanced Packaging

Support non-destructive inspection of internal package features and selected defects where visible access is blocked by silicon or package construction.

Thermal

PCB Hot-Spot Location

Identify localized heating around ICs, regulators, MOSFETs, resistors, connectors, traces and other board-level components.

Thermal

Shorts, Leakage & Power Dissipation

Use abnormal or unexpected heating as a fast visual clue to electrical faults, excessive power dissipation or localized current paths.

Thermal

Device & Component Characterization

Observe temperature response in semiconductor devices, LEDs, sensors, resistors, microelectronics and other components under controlled operating conditions.

See the Applications

SWIR and Thermal Microscopy in Practice

SWIR Semiconductor Inspection

Explore SWIR imaging for wafer, die, package and through-silicon inspection.

Thermal Microscopy for Electronics

Visualize temperature distribution across PCBs, components, semiconductor devices and small samples during troubleshooting and failure analysis.

Combined Failure-Analysis Workflow

Use Each Imaging Method Where It Adds the Most Information

For complex semiconductor or electronics problems, a combined workflow can reduce trial-and-error by first locating the problem spatially, then examining the relevant structure or interface in greater detail.

Define the Failure

Document the sample, suspected feature size, operating condition, required field of view and whether the issue is structural, thermal or both.

Locate Abnormal Behavior

For powered electronics, thermal microscopy can identify hot spots, asymmetry, abnormal gradients or unexpected temperature rise.

Inspect Hidden Structure

Where silicon blocks visible access, use SWIR microscopy to examine selected subsurface features, interfaces, cracks, voids or alignment.

Correlate & Confirm

Use the imaging results to guide electrical measurements, component inspection, design changes, rework or deeper root-cause analysis.

Pembroke Microscopy Solutions

Products and Configurations for SWIR and Thermal Inspection

Pembroke configurable SWIR microscope system

SWIR Microscope Systems

Custom microscope configurations for wafer, die, MEMS, TSV and bonded-interface inspection.

  • Selectable field of view
  • Fixed or zoom magnification
  • Co-axial, LED or laser illumination
  • Manual or motorized positioning
View SWIR Microscopes
SenS 1920 high-resolution InGaAs SWIR camera

High-Resolution SWIR Cameras

SenS 1920 and SenS 1280 cameras provide high spatial sampling for detailed inspection and microscope integration.

  • SenS 1920: 1920 × 1080, 8 µm pixels
  • SenS 1280: 1280 × 1024, 10 µm pixels
  • 900-1700 nm InGaAs response
  • Multiple camera configurations
Compare SWIR Cameras
Pembroke thermal imaging microscope system for PCB, IC and semiconductor analysis

Thermal Imaging Microscopes

Configured LWIR microscope systems for quantitative temperature mapping of PCBs, ICs, semiconductor devices and small materials samples.

  • 640 × 512 LWIR sensor format
  • Approximately 20 µm IC/PCB spatial resolution, setup dependent
  • Macro and objective lens options
  • Radiometric video plus electrical synchronization options
View Thermal Microscopes

Define the Complete Imaging Requirement

Information That Helps Pembroke Recommend the Right System

  • Sample type: wafer, die, package, PCB, component or material.
  • Smallest feature or hot spot: the smallest area that must be resolved or localized.
  • Field of view: full device, package region, board section or microscope-scale area.
  • Working distance and clearance: available space above the sample and any fixture constraints.
  • For SWIR: silicon thickness, wavelength/illumination constraints and transmission or reflection geometry.
  • For thermal: expected temperature range, operating state, startup/load conditions and transient behavior.
  • Integration: camera interface, triggering, software, positioning and existing optical/mechanical hardware.

System Performance Depends on More Than the Camera

For SWIR, wavelength, lens transmission, magnification, working distance, sample construction and illumination geometry affect contrast and detectability. For thermal microscopy, field of view, working distance, operating condition and the size of the thermal feature determine whether the measurement is useful. Pembroke can help define the complete imaging configuration rather than selecting a camera in isolation.

Pembroke Application Support

Move from a Sample Problem to a Working Microscopy Setup

Pembroke Instruments can help evaluate resolution, field of view, pixel size, camera sensitivity, cooling, optics, illumination, working distance, magnification, filters, positioning, software and mechanical integration. The goal is to configure the imaging method around the inspection problem—not force the application around a camera specification.