Description
The modular design is able to match a variety of experimental geometries and configurations. It features an integrated slit holder and filter insertion unit, as well as a motorized grating positioning. Download maxLIGHT datasheet.
SXR Grating | SXR Grating | XUV Grataing | XUV Grating | XUV Grating | VUV Grating | VUV Grating | |
Wavelength (nm) | 1-20 | 1-20 | 5-80 | 5-80 | 5-80 | 40-200 | 40-200 |
Operation Mode | Slitless | Slitless | slitless | slitless | slitless | slitless | slitless |
Source Distance [m] | Flexible | Flexible | Flexible | Flexible | Flexible | Flexible | Flexible |
Wavelength [nm] | 1-10 | 3-20 | 5-40 | 10-60 | 25-80 | 40-120 | 100-200 |
Flat field size [mm] | 35 | 45 | 60 | 55 | 50 | 75 | 70 |
Dispersion [nm/mm] | 0.2-0.35 | 0.3-0.4 | 0.5-0.65 | 0.7-1.1 | 0.9-1.3 | 0.9-1.3 | 1.2-1.6 |
Resolution [nm] | <0.015 | < 0.017 | <0.028 | <0.045 | <0.05 | <0.05 | <0.07 |
Main Characteristics
-
flat-field grazing-incidence spectrograph
-
proprietary H+P design for direct source imaging and maximum light collection
-
wavelength range from 1 to 200 nm
-
SXR 1-20nm / XUV 5-80nm / VUV 40-200nm
-
other wavelength ranges on request​
-
operating pressure <10^-6 mbar
-
modular, adaptable design
-
turn-key, hassle-free operation
-
maxLIGHT pro datasheet
Applications
-
high harmonic generation (HHG) radiation
-
high intensity laser-matter interaction
-
undulator and free-electron-laser (FEL) radiation
-
magnetically confined plasmas
-
fusion research
-
characterization of line-emission sources
-
EUV source calibration
Â
Light Detection Options
Our spectrometers can be operated with all state-of-the-art detection systems:
-
x-ray CCD cameras for highest resolution, large dynamic range and absolute signal strength. See our Greateyes CCD cameras for X-Ray spectroscopy
-
large-area MCPs for broadest wavelength coverage and gated / intensified detection
We will select and supply the detector that best fits your application
Comparative Specifications and Features
easyLIGHT | maxLIGHT | maxLIGHT+ | |
Flat-field grazing-incidence spectrograph | NO | YES | YES |
Normal-incidence spectrograph and monochromator | YES | NO | NO |
Flexible choice of detectors: x-ray CCD or MCP/fiber | YES | YES | YES |
Operating pressure <10-6 mbar | YES | YES | YES |
Customizable according to user requirements | YES | YES | YES |
Proprietary slit-less design for high efficiency | SLIT | YES | YES |
Grating blaze for additional efficiency increase | NO | NO | YES |
Motorized closed-loop 3D grating positioning | NO | NO | YES |
Manual 1D grating positioning | NO | YES | NO |
Motorized grating rotation | YES | NO | NO |
Filter insertion unit | NO | NO | YES |
Vacuum gate valve | NO | NO | YES |
Entrance and exit slits continuously variable | YES | N/A | N/A |